Outils pour utilisateurs

Outils du site


sunfluidh:simulation_management_setup_namelist

Différences

Ci-dessous, les différences entre deux révisions de la page.

Lien vers cette vue comparative

Les deux révisions précédentesRévision précédente
Prochaine révisionLes deux révisions suivantes
sunfluidh:simulation_management_setup_namelist [2016/11/28 23:02] yannsunfluidh:simulation_management_setup_namelist [2016/11/29 12:41] yann
Ligne 74: Ligne 74:
 ==== Field_Recording_Rate ==== ==== Field_Recording_Rate ====
    * Type : Real value    * Type : Real value
-   * This variable defines the recording rate, __in time units__ , of instantaneous fields (for instance, when "Field_Recording_Rate=1.5" an instantaneous field file is created as soon as the time value is a multiple of 1.5).\\ Instantaneous field files are named res_xxxxxxx_yyyyy.d ('yyyyy' is the subdomain number for simulations based on the MPI domain-decomposition approach, 'xxxxxxx' is the file number). The physical quantities bounded to the intantaneous fields are defined with the namelist "Instantaneous_Fields_Listing".+   * This variable defines the recording rate, __in time units__ , of instantaneous fields (for instance, when "Field_Recording_Rate=1.5" an instantaneous field file is created as soon as the time value is a multiple of 1.5).\\ Instantaneous field files are named res_xxxxxxx_yyyyy.d ('yyyyy' is the subdomain number for simulations based on the MPI domain-decomposition approach, 'xxxxxxx' is the file number). The intantaneous fields of the physical quantities are defined with the namelist "Instantaneous_Fields_Listing".
 ==== Start_Time_For_Statistics ==== ==== Start_Time_For_Statistics ====
    * Type : Real value    * Type : Real value
Ligne 83: Ligne 83:
 ==== Probe_Recording_Rate ==== ==== Probe_Recording_Rate ====
    * Type : Integer value    * Type : Integer value
-   * This variable defines the recording rate, __in time iteration units__ , of time series associated to the probes distributed over the domain (see the namelist "Probe_Location"). The physical quantities bounded to the probe time-series are defined with the namelist "Probe_Quantities_Enabled". For instance, when "Probe_Recording_Rate=10", a new value is added to probe time-series for all time iteration numbers that are a multiple of 10).+   * This variable defines the recording rate, __in time iteration units__ , of time series associated to the probes distributed over the domain (see the namelist "Probe_Location"). The physical quantities linked to the probe time-series are defined with the namelist "Probe_Quantities_Enabled". For instance, when "Probe_Recording_Rate=10", a new value is added to probe time-series for all time iteration numbers that are a multiple of 10).
sunfluidh/simulation_management_setup_namelist.txt · Dernière modification : 2022/01/10 10:34 de yann