Ligne 109: Ligne 109:
    * Type : Real value    * Type : Real value
    * This variable defines the recording rate, __in time units__ , of instantaneous fields (for instance, when "Field_Recording_Rate=1.5" an instantaneous field file is created as soon as the time value is a multiple of 1.5).\\ Instantaneous field files are named res_xxxxxxx_yyyyy.d ('yyyyy' is the subdomain number for simulations based on the MPI domain-decomposition approach, 'xxxxxxx' is the file number). The intantaneous fields of the physical quantities are defined with the namelist "Instantaneous_Fields_Listing".    * This variable defines the recording rate, __in time units__ , of instantaneous fields (for instance, when "Field_Recording_Rate=1.5" an instantaneous field file is created as soon as the time value is a multiple of 1.5).\\ Instantaneous field files are named res_xxxxxxx_yyyyy.d ('yyyyy' is the subdomain number for simulations based on the MPI domain-decomposition approach, 'xxxxxxx' is the file number). The intantaneous fields of the physical quantities are defined with the namelist "Instantaneous_Fields_Listing".
 +
 +**InstantaneousFields_RecordingStartTime**
 +   * Type : Real value
 +   * This variable sets the time threshold from which the record of instantaneous fields begins. It must be used along with the next variable "InstantaneousFields_TimeRecordingRate". This value is defined in time units.
 +
 +**InstantaneousFields_TimeRecordingRate**
 +   * Type : Real value
 +   * This variable defines the recording rate, __in time units__ , of instantaneous fields. For instance, when "InstantaneousFields_TimeRecordingRate=1.5" a file is created at every 1.5 time units from the start time provided by the variable "InstantaneousFields_RecordingStartTime".\\ 
 +
 +**InstantaneousFields_StartTimeIterationRecording**
 +   * Type : Integer value
 +   * This variable sets the time-iteration threshold from which the record of instantaneous fields begins. It must be used along with the next variable "InstantaneousFields_TimeIterationRecordingRate". This value is defined in time-iteration units (number of time steps).
 +
 +**InstantaneousFields_TimeIterationRecordingRate**
 +   * Type : Integer value
 +   * This variable defines the recording rate, __in time-iteration units__ , of instantaneous fields. For instance, when "InstantaneousFields_TimeIterationRecordingRate=100" a file is created at every 100 time steps from the threshold provided by the variable "InstantaneousFields_StartTimeIterationRecording".\\ 
 +
 +**InstantaneousFields_RecordingReset**
 +   * Type : Boolean value
 +   * When this variable is set to "true", the ID number of file 'xxxxxxx' is set to zero for the next simulation.
 +
 +
 +<note>
 +Keep in mind : 
 +   * Instantaneous field files are named res_xxxxxxx_yyyyy.d. T
 +   * The number 'yyyyy' stands for the subdomain number on which fields are recorded for simulations based on the MPI domain-decomposition approach. When the domain decomposition approach is not used (just one domain), 'yyyyy=00000' is the default value.
 +    'xxxxxxx' is the ID number of the file. 'xxxxxxx' is incremented by one for each new file created. 
 +   * The intantaneous fields of the physical quantities written in each file are defined with the namelist "Instantaneous_Fields_Listing".
 +</note>
 +
  