sunfluidh:simulation_management_setup_namelist [2019/11/13 14:40] yannsunfluidh:simulation_management_setup_namelist [2019/11/13 15:07] yann
Ligne 19: Ligne 19:
                              Simulation_Backup_Rate                 = 1000   ,                               Simulation_Backup_Rate                 = 1000   , 
                              Simulation_Checking_Rate = 200 ,                               Simulation_Checking_Rate = 200 , 
-                             Fields_Recording_Rate = 1.D+00 ,+                             InstantaneousFields_TimeRecordingRate= 1.0D+00  , 
 +                             InstantaneousFields_RecordingStartTime= 0.0    ,
                              Probe_Recording_Rate                   = 10     ,                              Probe_Recording_Rate                   = 10     ,
                              Start_Time_For_Statistics= 1.D+2               ,                               Start_Time_For_Statistics= 1.D+2               , 
Ligne 102: Ligne 103:
 **Simulation_Backup_Rate**  **Simulation_Backup_Rate** 
    * Type : Integer value    * Type : Integer value
-   * This variable defines the recording rate, __in time iteration units__ , of the backup files (for instance, when "Simulation_Backup_Rate=1000" a data backup is carried out for all time iteration numbers that are a multiple of 1000).\\ Backup data are dispatched in two files that are named save_var_yyyyy_n.d and save_fld_yyyyy_n.d ('yyyyy' is the subdomain number for simulations based on the MPI domain-decomposition approach, n= 1 or 2 for temporary backup files and n=3 for the backup files created during the last time step of the simulation).+   * This variable defines the recording rate, __in time iteration unit__ , of the backup files (for instance, when "Simulation_Backup_Rate=1000" a data backup is carried out for all time iteration numbers that are a multiple of 1000).\\ Backup data are dispatched in two files that are named save_var_yyyyy_n.d and save_fld_yyyyy_n.d ('yyyyy' is the subdomain number for simulations based on the MPI domain-decomposition approach, n= 1 or 2 for temporary backup files and n=3 for the backup files created during the last time step of the simulation).
  
 ==== - For snapshot files : ==== ==== - For snapshot files : ====
- 
-**Field_Recording_Rate**  
-   * Type : Real value 
-   * This variable defines the recording rate, __in time units__ , of instantaneous fields (for instance, when "Field_Recording_Rate=1.5" an instantaneous field file is created as soon as the time value is a multiple of 1.5).\\ Instantaneous field files are named res_xxxxxxx_yyyyy.d ('yyyyy' is the subdomain number for simulations based on the MPI domain-decomposition approach, 'xxxxxxx' is the file number). The intantaneous fields of the physical quantities are defined with the namelist "Instantaneous_Fields_Listing". 
  
 **InstantaneousFields_RecordingStartTime** **InstantaneousFields_RecordingStartTime**
    * Type : Real value    * Type : Real value
-   * This variable sets the time threshold from which the record of instantaneous fields begins. It must be used along with the next variable "InstantaneousFields_TimeRecordingRate". This value is defined in time units.+   * This variable sets the time threshold from which the record of instantaneous fields begins. It must be used along with the next variable "InstantaneousFields_TimeRecordingRate". This value is defined in time unit.
  
 **InstantaneousFields_TimeRecordingRate** **InstantaneousFields_TimeRecordingRate**
    * Type : Real value    * Type : Real value
-   * This variable defines the recording rate, __in time units__ , of instantaneous fields. For instance, when "InstantaneousFields_TimeRecordingRate=1.5" a file is created at every 1.5 time units from the start time provided by the variable "InstantaneousFields_RecordingStartTime".\\ +   * This variable defines the recording rate, __in time unit__ , of instantaneous fields. For instance, when "InstantaneousFields_TimeRecordingRate=1.5" a file is created at every 1.5 time unit from the start time provided by the variable "InstantaneousFields_RecordingStartTime".\\ 
  
 **InstantaneousFields_StartTimeIterationRecording** **InstantaneousFields_StartTimeIterationRecording**
    * Type : Integer value    * Type : Integer value
-   * This variable sets the time-iteration threshold from which the record of instantaneous fields begins. It must be used along with the next variable "InstantaneousFields_TimeIterationRecordingRate". This value is defined in time-iteration units (number of time steps).+   * This variable sets the time-iteration threshold from which the record of instantaneous fields begins. It must be used along with the next variable "InstantaneousFields_TimeIterationRecordingRate". This value is defined in time-iteration unit (number of time steps).
  
 **InstantaneousFields_TimeIterationRecordingRate** **InstantaneousFields_TimeIterationRecordingRate**
Ligne 128: Ligne 125:
 **InstantaneousFields_RecordingReset** **InstantaneousFields_RecordingReset**
    * Type : Boolean value    * Type : Boolean value
-   * When this variable is set to "true", the ID number of file 'xxxxxxx' is set to zero for the next simulation.+   * When this variable is set to "true", the ID number of file 'xxxxxxx' is set to zero for the next simulation. This is useful for resetting the file numbering when a simulation is split into several successive parts.
  
  
Ligne 136: Ligne 133:
    * The number 'yyyyy' stands for the subdomain number on which fields are recorded for simulations based on the MPI domain-decomposition approach. When the domain decomposition approach is not used (just one domain), 'yyyyy=00000' is the default value.    * The number 'yyyyy' stands for the subdomain number on which fields are recorded for simulations based on the MPI domain-decomposition approach. When the domain decomposition approach is not used (just one domain), 'yyyyy=00000' is the default value.
     'xxxxxxx' is the ID number of the file. 'xxxxxxx' is incremented by one for each new file created.      'xxxxxxx' is the ID number of the file. 'xxxxxxx' is incremented by one for each new file created. 
-   * The intantaneous fields of the physical quantities written in each file are defined with the namelist "Instantaneous_Fields_Listing".+   * The instantaneous fields of the physical quantities written in each file are defined with the namelist "Instantaneous_Fields_Listing".
 </note> </note>
  
 +<WRAP important>
 + This set of variables must be used in respect of one rule : the user wants to define the recording rate of files either in time unit or in number of time steps (time-ieration unit). In any case, the correct couple of variable must be used.
 +   * "InstantaneousFields_RecordingStartTime" and "InstantaneousFields_TimeRecordingRate" in  time unit.
 +   * "InstantaneousFields_StartTimeIterationRecording" and "InstantaneousFields_TimeIterationRecordingRate" in number of time steps.
 +
 +</WRAP>
  
 ==== - For statistics files : ==== ==== - For statistics files : ====