sunfluidh:simulation_management_setup_namelist [2019/11/13 15:39] yannsunfluidh:simulation_management_setup_namelist [2019/12/13 15:50] yann
Ligne 138: Ligne 138:
  
 <WRAP important> <WRAP important>
- This set of variables must be used in respect of one rule : the user wants to define the recording rate of files either in time unit or in number of time steps (time-ieration unit). In any case, the correct couple of variable must be used. + This set of variables must be used in respect of one rule : the user wants to define the recording rate of files either in time unit or in number of time steps (time-ieration unit). In any case, the correct couple of variables must be used. 
-   * "InstantaneousFields_RecordingStartTime" and "InstantaneousFields_TimeRecordingRate" in  time unit. +   * "InstantaneousFields_RecordingStartTime" and "InstantaneousFields_TimeRecordingRate" (in time unit)
-   * "InstantaneousFields_StartTimeIterationRecording" and "InstantaneousFields_TimeIterationRecordingRate" in number of time steps.+   * "InstantaneousFields_StartTimeIterationRecording" and "InstantaneousFields_TimeIterationRecordingRate" (in number of time steps).
  
 </WRAP> </WRAP>
Ligne 159: Ligne 159:
    * This variable defines the recording rate, __in time iteration unit__ (number of time steps), of time series from probes distributed over the domain (see the namelist "Probe_Location"). The physical quantities linked to the probe time-series are defined with the namelist "Probe_Quantities_Enabled". For instance, when "Probe_TimeIterationRecordingRate=10", a new value is added to probe time-series at every 10 time steps from the threshold defined with "Probe_StartTimeIterationRecording").    * This variable defines the recording rate, __in time iteration unit__ (number of time steps), of time series from probes distributed over the domain (see the namelist "Probe_Location"). The physical quantities linked to the probe time-series are defined with the namelist "Probe_Quantities_Enabled". For instance, when "Probe_TimeIterationRecordingRate=10", a new value is added to probe time-series at every 10 time steps from the threshold defined with "Probe_StartTimeIterationRecording").
  
-**Probe_TimeIterationRecordingRate**+**Probe_StartTimeIterationRecording**
    * Type : Integer value    * Type : Integer value
    * This variable defines the threshold from which the probe time-series start (in time iteration unit)    * This variable defines the threshold from which the probe time-series start (in time iteration unit)
sunfluidh/simulation_management_setup_namelist.txt · Dernière modification : 2022/01/10 10:34 de yann