Outils pour utilisateurs

Outils du site


sunfluidh:outlet_boundary_conditions_setup_namelist

Différences

Ci-dessous, les différences entre deux révisions de la page.

Lien vers cette vue comparative

Les deux révisions précédentesRévision précédente
Prochaine révision
Révision précédente
sunfluidh:outlet_boundary_conditions_setup_namelist [2016/11/28 17:35] – [Type_of_BC] yannsunfluidh:outlet_boundary_conditions_setup_namelist [2016/11/29 15:34] (Version actuelle) – [Pressure_Reference_Value] yann
Ligne 1: Ligne 1:
  
 ===== Outlet_Boundary_Condition ===== ===== Outlet_Boundary_Condition =====
-This data setup are used to define the outflow condition features. The outflow geometry is restricted to rectangular/line forms in 3D/2D configuration. In the particular case of cylindrical geometries, the outlets can be circular, annular or bowed retangular. In fact, the geometry of the outlet fits the grid topology.\\+This data setup are used to define the outflow condition features. The outflow geometry is restricted to rectangular/line forms in 3D/2D configuration. In the particular case of cylindrical geometries, the outlets can be circular, annular or bowed rectangular. In fact, the geometry of the outlet fits the grid topology.\\
  
 ===== Full data set of the namelist ===== ===== Full data set of the namelist =====
Ligne 10: Ligne 10:
      Start_Coordinate_of_First_Span = -0.01, End_Coordinate_of_First_Span = 0.01,      Start_Coordinate_of_First_Span = -0.01, End_Coordinate_of_First_Span = 0.01,
      Start_Coordinate_of_Second_Span= 0.0  , End_Coordinate_of_Second_Span= 0.0 ,      Start_Coordinate_of_Second_Span= 0.0  , End_Coordinate_of_Second_Span= 0.0 ,
-     Pressure_Reference_Value       1.0    ,  Length_Scale                 = 1.0  ,+     Pressure_Reference_Value       0.0    ,  Length_Scale                 = 1.0  ,
      Flow_Direction= 1 ,      Flow_Direction= 1 ,
      End_of_Data_Block= .true. /      End_of_Data_Block= .true. /
Ligne 21: Ligne 21:
    * When the the normal vector is oriented along the J-direction, the first span direction is I and the second is K.    * When the the normal vector is oriented along the J-direction, the first span direction is I and the second is K.
    * When the the normal vector is oriented along the K-direction, the first span direction is I and the second is J.    * When the the normal vector is oriented along the K-direction, the first span direction is I and the second is J.
 +   * By default the domain is enclosed. The boundary conditions defined by default at the ends of the domain are walls. When an outlet is placed at the end of the domain, it replaces the wall conditions over the outflow area.
    * Don't forget to set the boolean data “End_of_Data_Block” at the end of the namelist. A “.true.” value means the end of the data block when several namelists are used to create several outlets.     * Don't forget to set the boolean data “End_of_Data_Block” at the end of the namelist. A “.true.” value means the end of the data block when several namelists are used to create several outlets. 
  
Ligne 63: Ligne 64:
    * This value is set to 1 or -1. It indicates the presumed direction of the outflow in accordance to the position of the outlet. If the outflow is oriented along the increasing or decreasing index (for a given direction) the value is set to 1 or -1, respectively.    * This value is set to 1 or -1. It indicates the presumed direction of the outflow in accordance to the position of the outlet. If the outflow is oriented along the increasing or decreasing index (for a given direction) the value is set to 1 or -1, respectively.
 ==== Pressure_Reference_Value ==== ==== Pressure_Reference_Value ====
-   * Type : Real value +   * Type : Real value (__** Not for the release SUNFLUIDH_EDU**__ ) 
-   * Reference value of the imposed pressure used when "OUT_PF" or "FREEBC" condition is used. This data is omitted when the "OUTLET" condition is used. At present, it is advised to set the pressure reference value to zero.+   * Reference value of the imposed dynamical pressure used when "OUT_PF" or "FREEBC" condition is used. This data is omitted when the "OUTLET" condition is used. At present, it is advised to set the pressure reference value to zero.
 ==== Length_Scale ==== ==== Length_Scale ====
-   * Type : Real value+   * Type : Real value (__** Not for the release SUNFLUIDH_EDU**__ )
    * Distance between the outlet plane and the position where the pressure reference value is imposed behind the outlet plane when the "FREEBC" condition is used. This data is omitted when the "OUTLET" or the "OUT_PF" condition is used.    * Distance between the outlet plane and the position where the pressure reference value is imposed behind the outlet plane when the "FREEBC" condition is used. This data is omitted when the "OUTLET" or the "OUT_PF" condition is used.
 ==== End_of_Data_Block ==== ==== End_of_Data_Block ====
    * Type : boolean value    * Type : boolean value
    * Specify the end of the namelist or a group of this type of namelist (if true).    * Specify the end of the namelist or a group of this type of namelist (if true).
sunfluidh/outlet_boundary_conditions_setup_namelist.1480350903.txt.gz · Dernière modification : 2016/11/28 17:35 de yann

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki