Outils pour utilisateurs

Outils du site


sunfluidh:temperature_initialization_namelist

Différences

Ci-dessous, les différences entre deux révisions de la page.

Lien vers cette vue comparative

Les deux révisions précédentesRévision précédente
Prochaine révision
Révision précédente
sunfluidh:temperature_initialization_namelist [2016/11/18 14:53] – [White_Noise_Magnitude_For_Temperature] yannsunfluidh:temperature_initialization_namelist [2016/11/18 15:55] (Version actuelle) – [Namelist Temperature_Initialization] yann
Ligne 1: Ligne 1:
 ===== Namelist "Temperature_Initialization" ===== ===== Namelist "Temperature_Initialization" =====
-This data setup is used to define the initial temperature field over the domain.\\+This data setup is used to define the initial temperature field over the domain for flows with heat transfer.\\ 
 +This namelist can be removed for isotherm flows.
  
 ===== Full data set of the namelist ===== ===== Full data set of the namelist =====
Ligne 8: Ligne 9:
                                White_Noise_Magnitude_For_Temperature= 0.0 /                                White_Noise_Magnitude_For_Temperature= 0.0 /
  
 +<note important> For low Mach-number flows, the user must ensure the coherence between the reference values of physical quantities defined in the namelist [[sunfluidh:fluid_properties_namelist|"Fluid_Properties"]] (temperature, density and molecular mass), the initial temperature field over the domain (defined here) and, if needed, the species mass fraction distribution defined in the namelist [[sunfluidh:species_initialization_namelist|"Species_Initialization"]] (if the gas is composed with multi-components).\\
 +Keep in mind that the reference value of thermodynamic pressure is calculated from the reference values of temperature, density and molecular mass of the fluid (see namelist [[sunfluidh:fluid_properties_namelist|"Fluid_Properties"]]). \\ The density field is then initialized from the fields of temperature (and species mass fractions if needed) by considering the thermodynamic pressure is uniform over the domain (low Mach-number hypothesis).</note>
  
 ----- -----
Ligne 15: Ligne 18:
    * Type : real value    * Type : real value
    * Reference temperature value.    * Reference temperature value.
 +   * Default value must be set by the user
  
 ==== Initial_Field_Option_For_Temperature  ==== ==== Initial_Field_Option_For_Temperature  ====
Ligne 21: Ligne 25:
      * 0 : Uniform distribution      * 0 : Uniform distribution
      * 1 or greater : Optional values associated to temperature field defined by the users in the appropriate fortran module (see module_user_define_init_fields.f90). The reference value can be used to define the temperature scale.       * 1 or greater : Optional values associated to temperature field defined by the users in the appropriate fortran module (see module_user_define_init_fields.f90). The reference value can be used to define the temperature scale. 
 +     * Default value = 0
    
 ==== White_Noise_Magnitude_For_Temperature ==== ==== White_Noise_Magnitude_For_Temperature ====
Ligne 26: Ligne 31:
    * Magnitude of the white noise on the temperature field.    * Magnitude of the white noise on the temperature field.
    * The magnitude is defined as a fraction of the local value in each cell ( i.e. 0.4 corresponds to 40% of the local value of temperature on the grid)    * The magnitude is defined as a fraction of the local value in each cell ( i.e. 0.4 corresponds to 40% of the local value of temperature on the grid)
 +   * Default value = 0
  
sunfluidh/temperature_initialization_namelist.1479477204.txt.gz · Dernière modification : 2016/11/18 14:53 de yann