sunfluidh:temperature_initialization_namelist
Ceci est une ancienne révision du document !
Table des matières
Namelist "Temperature_Initialization"
This data setup is used to define the initial temperature field over the domain.
Full data set
&Temperature_Initialization Temperature_Reference_Value = 293.0, Initial_Field_Option_For_Temperature= 0 , White_Noise_Magnitude_For_Temperature= 0.0 /
—–
Definition of the data set
Temperature_Reference_Value
- Type : real value
- Reference temperature value.
Initial_Field_Option_For_Temperature
- Type : integer value
- Option to define the distribution of the temperature over the domain :
- 0 : Uniform distribution
- 1 or greater : Optional values associated to temperature field defined by the users in the appropriate fortran module (see module_user_define_init_fields.f90). The reference value can be used to define the temperature scale.
White_Noise_Magnitude_For_Temperature
- Type : real value
- Magnitude of the white noise on the temperature field.
- The magnitude is defined as a fraction of the local value in each cell ( i.e. 0.4 corresponds to 40% of the local value)
Traductions de cette page:
- fr
sunfluidh/temperature_initialization_namelist.1479477116.txt.gz · Dernière modification : 2016/11/18 14:51 de yann