sunfluidh:external_force_namelist
Table des matières
Namelist "External_Force"
This data set is used to define an external force that steers the flow. Otherwise, it can be omitted.
Full data set of the namelist
&External_Force Force_Option_I_Direction= 0 , Force_Option_J_Direction= 0 , Force_Option_K_Direction= 0 , Force_Reference_Value_I_Direction= 0.0, Force_Reference_Value_J_Direction= 0, Force_Reference_Value_K_Direction= 0.0 /
Definition of the data set
Force_Option_I_Direction
- Type : Integer value
- This option selects the type of force on the I-component of the force vector.
- 0 : the force component is zero
- 1 : the force component is constant
- 2 : the force component is time dependent and depends on the mass flowrate (special case used for the simulation of a channel flow with periodical boundary conditions).
- 3 : the force component is time dependent and depends on both mass flowrate and wall friction (special case used for the simulation of a channel flow with periodical boundary conditions).
- Default value = 0
Force_Option_J_Direction
- Type : Integer value
- This option selects the type of force on the J-component of the force vector (see above).
- Default value = 0
Force_Option_K_Direction
- Type : Integer value
- This option selects the type of force on the J-component of the force vector (see above).
- Default value = 0
Force_Reference_Value_I_Direction
- Type : Real value
- Reference value of the force component along the I-direction.
- Default value = 0.0
Force_Reference_Value_J_Direction
- Type : Real value
- Reference value of the force component along the J-direction.
- Default value = 0.0
Force_Reference_Value_K_Direction
- Type : Real value
- Reference value of the force component along the K-direction.
- Default value = 0.0
Traductions de cette page:
sunfluidh/external_force_namelist.txt · Dernière modification : 2016/11/18 16:23 de yann